Timing setup is presently: 5 [14ns_FIX_G]



************************************************
 This mirrors all block A timing values into
 timing block B for efficiency in acqiring
 calibration data.

 The undo this, you must restart the program.
************************************************
Do you wish to proceed [y/n]? [n]: y
Block A:
BPoffset: 154   bTMD: 8   GD : 914    c0: 738   c1: 730   c2: 722   c3: 729
Block B:
BPoffset: 154   bTMD: 8   GD : 914    c0: 738   c1: 730   c2: 722   c3: 729
Sending parameters...
Prep() function status = 0
--Copying and transferring structure set...
--Initializing command...
--Executing command...
--Waiting for handshake completion...
<ctacf124>   CMD_DONE  (3)
--Post function loop...
OP TIMING SETUP VALUE = 5 [14ns_FIX_G]
Block delays = 914   914

[INFO  | 07/28/14 15:49:17]:
 == COPY TIMING PARAMS A-->B Command Status Summary ==

 Instrument    Location    Active            Status           | Instrument    Location    Active            Status           |
--------------------------------------------------------------|--------------------------------------------------------------|
  ctacf124      TEST3        *     (0) SUCCESS                |
[INFO  | 07/28/14 15:49:17]  Begin post-command status check/recovery:   ...

-- MatthewStedinger - 28 Jul 2014