 This mirrors all block A timing values into
 timing block B for efficiency in acqiring
 calibration data.

 The undo this, you must restart the program.
************************************************
Do you wish to proceed [y/n]? [n]: y
# pS to add ? [50]:
Block A:
BPoffset: 128   bTMD: 7   GD : 608    c0: 394   c1: 393   c2: 404   c3: 409
Block B:
BPoffset: 128   bTMD: 7   GD : 658    c0: 394   c1: 393   c2: 404   c3: 409
Sending parameters...
Prep() function status = 0
--Copying and transferring structure set...
--Initializing command...
--Executing command...
--Waiting for handshake completion...
<ctacf018>   CMD_DONE  (3)
--Post function loop...
OP TIMING SETUP VALUE = 5 [14ns_FIX_G]
Block delays = 608   658

[INFO  | 07/28/14 16:53:56]:
 == COPY TIMING PARAMS A-->B+0.5 nS Command Status Summary ==

 Instrument    Location    Active            Status           | Instrument    Location    Active            Status           |
--------------------------------------------------------------|--------------------------------------------------------------|
  ctacf018      20E          *     (0) SUCCESS                |
[INFO  | 07/28/14 16:53:56]  Begin post-command status check/recovery:   ...

-- MatthewStedinger - 28 Jul 2014

This topic: ACC/Bunch > WebHome > CBICManPage > CopyTimingParamsAToBPlus500pS
Topic revision: 28 Jul 2014, mgs9